The device initialization code resets the whole device, thus the initial controls set at probe are lost as adv7180_init_controls() are called before init_device(). Additionally the controls were never restored after the device where reset coming back from suspend. Solve this by separate the setup of the controls from the creation of them, and always set them up when the device is reset. Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@xxxxxxxxxxxx> Reviewed-by: Laurent Pinchart <laurent.pinchart+renesas@xxxxxxxxxxxxxxxx> --- * Changes since v1 - Fix spelling in commit message. --- drivers/media/i2c/adv7180.c | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) diff --git a/drivers/media/i2c/adv7180.c b/drivers/media/i2c/adv7180.c index 7b0387151c3a..8409ee9acc4f 100644 --- a/drivers/media/i2c/adv7180.c +++ b/drivers/media/i2c/adv7180.c @@ -700,7 +700,6 @@ static int adv7180_init_controls(struct adv7180_state *state) v4l2_ctrl_handler_free(&state->ctrl_hdl); return err; } - v4l2_ctrl_handler_setup(&state->ctrl_hdl); return 0; } @@ -898,6 +897,8 @@ static int init_device(struct adv7180_state *state) adv7180_set_field_mode(state); + __v4l2_ctrl_handler_setup(&state->ctrl_hdl); + /* register for interrupts */ if (state->irq > 0) { /* config the Interrupt pin to be active low */ -- 2.51.0