> > + rzn1_rtc_ops.read_offset = rzn1_rtc_read_offset; > > + rzn1_rtc_ops.set_offset = rzn1_rtc_set_offset; > > I guess this situation is not possible but let me ask. Do we care > about the very unlikely case where two RTCs are available and configured > differently? Because we are overwriting a static entry here. Maybe we > could have two static structures and pick the correct one during probe > instead. True, it is so highly unlikely that I didn't think of it. But theoretically possible, I'll fix.