On Thu, Sep 11, 2025 at 09:26:59PM +0530, Niranjan H Y wrote: > Add API snd_soc_get_volsw_clamped to read > the volume from device. This similar to > existing API snd_soc_get_volsw. But has > additional step to clamp the value to max value > if the register value is larger than max value. Why is this a separate API, what is the situation where we would want to report an invalid value from a control? I was thinking of just adding this to the existing operations rather than adding separate ones that need to be explicitly set.