From: Ping-Ke Shih <pkshih@xxxxxxxxxxx> For CEPT countries, ECC/DEC/(20)01 [1][2] decision enters into force on 8 November 2024; preferred date for implementation of this Decision shall be 8 May 2025. Update regulatory rule for Bosnia and Herzegovina accordingly. * LPI devices - 5945-6425 MHz - Restricted to indoor use only - Maximum mean e.i.r.p.: 23 dBm - Maximum mean e.i.r.p. density: 10 dBm/MHz * VLP devices - 5945-6425 MHz - Indoors and outdoors - Maximum mean e.i.r.p.: 14 dBm - Maximum mean e.i.r.p. density: 1 dBm/MHz [1] https://docdb.cept.org/implementation/16737 [2] https://docdb.cept.org/download/4685 Signed-off-by: Ping-Ke Shih <pkshih@xxxxxxxxxxx> --- db.txt | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/db.txt b/db.txt index 12ac14766a69..81ff14ecaac3 100644 --- a/db.txt +++ b/db.txt @@ -201,6 +201,9 @@ country AZ: DFS-ETSI # EU decision 2005/513/EC: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:02005D0513-20070213 # EU decision 2006/771/EC: https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:02008D0432-20080611 # Harmonized CEPT countries (July 2019): https://www.ecodocdb.dk/download/25c41779-cd6e/Rec7003e.pdf +# Harmonized CEPT countries for 6 GHz (ECC Decision (20)01) +# https://docdb.cept.org/implementation/16737 +# https://docdb.cept.org/download/4685 country BA: DFS-ETSI (2400 - 2483.5 @ 40), (100 mW) (5150 - 5250 @ 80), (200 mW), NO-OUTDOOR, AUTO-BW, wmmrule=ETSI @@ -208,6 +211,7 @@ country BA: DFS-ETSI (5470 - 5725 @ 160), (500 mW), DFS, wmmrule=ETSI # short range devices (ETSI EN 300 440-1) (5725 - 5875 @ 80), (25 mW) + (5945 - 6425 @ 320), (23), NO-OUTDOOR # 60 GHz band channels 1-4, ref: Etsi En 302 567 (57000 - 66000 @ 2160), (40) -- 2.25.1