On 4/8/2025 11:36 AM, Aditya Kumar Singh wrote:
At present, during PCI shutdown, the power down is only executed for a single device. However, when operating in a group, all devices need to be powered down simultaneously. Failure to do so will result in a firmware assertion. Hence, introduce a new ath12k_pci_hw_group_power_down() and call it during power down. This will ensure that all partner devices are properly powered down. Tested-on: QCN9274 hw2.0 PCI WLAN.WBE.1.3.1-00173-QCAHKSWPL_SILICONZ-1 Tested-on: QCN9274 hw2.0 PCI WLAN.WBE.1.4.1-00199-QCAHKSWPL_SILICONZ-1 Tested-on: WCN7850 hw2.0 PCI WLAN.HMT.1.0.c5-00481-QCAHMTSWPL_V1.0_V2.0_SILICONZ-3 Signed-off-by: Aditya Kumar Singh <aditya.kumar.singh@xxxxxxxxxxxxxxxx>
Reviewed-by: Vasanthakumar Thiagarajan <vasanthakumar.thiagarajan@xxxxxxxxxxxxxxxx>