Re: [RFC PATCH 11/17] Documentation/rv: Add documentation about hybrid automata

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 19/08/25 10:53, Juri Lelli wrote:
> Hi!
> 
> On 14/08/25 17:08, Gabriele Monaco wrote:

...

> > +  static bool verify_constraint(enum states curr_state, enum events event,
> > +				 enum states next_state)
> > +  {
> > +	bool res = true;
> > +
> > +	/* Validate guards as part of f */
> > +	if (curr_state == enqueued && event == sched_switch_in)
> > +		res = get_env(clk) < threshold;
> > +	else if (curr_state == dequeued && event == sched_wakeup)
> > +		reset_env(clk);
> > +
> > +	/* Validate invariants in i */
> > +	if (next_state == curr_state)
> > +		return res;
> > +	if (next_state == enqueued && res)
> > +		start_timer(clk, threshold);
> 
> So, then the timer callback checks the invariant and possibly reports
> failure?

Ah, OK. The 'standard' ha_monitor_timer_callback just reports failure
(react) in case the timer fires. Which makes sense as at that point the
invariant is broken. Maybe add some wording to highlight this?





[Index of Archives]     [Kernel Newbies]     [Security]     [Netfilter]     [Bugtraq]     [Linux FS]     [Yosemite Forum]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Samba]     [Video 4 Linux]     [Device Mapper]     [Linux Resources]