On 04/09/2025 15:31, Konrad Dybcio wrote:
From: Konrad Dybcio <konrad.dybcio@xxxxxxxxxxxxxxxx>
This was evidently wrong, as exemplified by the core failing to reset
at probe (which would be completed by the IRQ firing).
Fix it.
Fixes: 7cfa2e758bf4 ("arm64: dts: qcom: sc8280xp: camss: Add CCI definitions")
Signed-off-by: Konrad Dybcio <konrad.dybcio@xxxxxxxxxxxxxxxx>
---
arch/arm64/boot/dts/qcom/sc8280xp.dtsi | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/arch/arm64/boot/dts/qcom/sc8280xp.dtsi b/arch/arm64/boot/dts/qcom/sc8280xp.dtsi
index 225233a37a4fd9f3d65735915c0338a993a322d1..18b5cb441f955f7a91204376e05536b203f3e28b 100644
--- a/arch/arm64/boot/dts/qcom/sc8280xp.dtsi
+++ b/arch/arm64/boot/dts/qcom/sc8280xp.dtsi
@@ -4292,7 +4292,7 @@ cci3: cci@ac4d000 {
compatible = "qcom,sc8280xp-cci", "qcom,msm8996-cci";
reg = <0 0x0ac4d000 0 0x1000>;
- interrupts = <GIC_SPI 650 IRQ_TYPE_EDGE_RISING>;
+ interrupts = <GIC_SPI 771 IRQ_TYPE_EDGE_RISING>;
clocks = <&camcc CAMCC_CAMNOC_AXI_CLK>,
<&camcc CAMCC_SLOW_AHB_CLK_SRC>,
Reviewed-by: Bryan O'Donoghue <bryan.odonoghue@xxxxxxxxxx>